POWER knob at the left of panel and short press (<5s) UP or DOWN or SET knob to use the storage setting temperature into
current work temperature and air volume.
(Notice: up, down, set refer to storage term1, term2, term3)
4. Temperature comp temperature and calibration
Under normal working condition, hold down both POWER knob at right of panel and “ ” knob on the handle to calibrate
soldering station temperature (diagram18). Temperature value can be calibrated by pressing UP or DOWN knobs. Pressing the
SET knob to confirm storage and quit from this calibration (diagram 11).
5. Standby
In normal working condition, press POWER key at the right of panel to make the device be standby (diagram 2). Make the
power off, at the same time, the soldering station is off and the whole station will off when the temperature is low to 100°C.
6. Error/Fault indication
A. When “H-E” is displayed on the screen A, there is no temperature (diagram 19),which indicates that the heating element
fails.
B. When “S-E” is displayed on the screen A, there is a fault in sensor (diagram 20), which signifies that there is something
wrong with the sensor or the related circuit of the sensor.
III. Conversion of temperature unit
Under the power off condition, hold down the UP, DOWN and SET knob and then put power on to switch °C/°F.