POWER knob at the left of panel and short press (<5s) UP or DOWN or SET knob to use the storage setting temperature into 

current work temperature and air volume.
(Notice: up, down, set refer to storage term1, term2, term3)

4. Temperature comp temperature and calibration

Under normal working condition, hold down both POWER knob at right of panel and “ ” knob on the handle to calibrate 

soldering station temperature (diagram18). Temperature value can be calibrated by pressing UP or DOWN knobs. Pressing the 

SET knob to confirm storage and quit from this calibration (diagram 11).

5. Standby

In normal working condition, press POWER key at the right of panel to make the device be standby (diagram 2). Make the 

power off, at the same time, the soldering station is off and the whole station will off when the temperature is low to 100°C.

   

6. Error/Fault indication

A.  When “H-E” is displayed on the screen A, there is no temperature (diagram 19),which indicates that the heating element 

fails.

B.  When “S-E” is displayed on the screen A, there is a fault in sensor (diagram 20), which signifies that there is something 

wrong with the sensor or the related circuit of the sensor.

III. Conversion of temperature unit

Under the power off condition, hold down the UP, DOWN and SET knob and then put power on to switch °C/°F.

Summary of Contents for 21-10130 UK+EU

Page 1: ...www element14 com www farnell com www newark com www cpc co uk TM TM Page 1 V1 0 23 08 18 2 in 1 SMD Rework Station 21 10130 UK EU User Manual ...

Page 2: ...f and allow sufficient time for the tip to cool down The soldering tip should be cleaned by wiping it on the cleaning sponge provided This will help get rid of the burnt solder or fluxes that cause oxidation on the soldering tip Not cleaning the tip might lead to improper soldering Never use it as a hair drier and touch the heating element or blow the skin directly Don t operate with wet hands or ...

Page 3: ...elay and then be in the condition of dormancy and Standby Cold Air Hot Air Rework Station Air blowing made by the machine and stopping heating Malfunction Alert Heating Elements Displaying H E Sensor Displaying H E Specifications are subject to change without prior notice Function diagram 1 Rework station nozzle 2 Hot air handle bracket 3 Hot air handle button group 4 Rework station handle 5 B scr...

Page 4: ...www element14 com www farnell com www newark com www cpc co uk TM TM Page 4 V1 0 23 08 18 Interchangeable soldering tips of soldering station 900M tip OutDiam Φ6 5 Nozzles ...

Page 5: ...held paint strippers shall include the substance of following A fire may result if the appliance is not used with care therefore be careful when using the appliance in places where there are combustible materials Do not apply to the same place for a long time Do not use in presence of an explosive atmosphere Be aware that heat may be conducted to combustible materials that are out of sight Place t...

Page 6: ...of hot air station Adjustment of air volume Blowing cold air of rework station Awake hot air of rework station Installation The brackets for the handles must be installed when operating for the first time Please see the following illustration 1 Please fix the bracket by tightening the four screws according to the illustration and your personal habit 2 According to your selection dismantle the two ...

Page 7: ...f hot air reworking station A If screen A shines C F setting temperature through operating the button of panel If screen A doesn t shine C F you must press the SET button to switch to shine C F of screen A then the station Under the setting condition Then you can press SET button to set hot air rework station s temperature and the main temperature area shines the setting temperature you can press ...

Page 8: ...k station You can press UP knob or DOWN knob to adjust hot air volume and the main temperature area indicators setting volume 4s no press or press SET knob you can keep the volume and quit out this setting at that time you can adjust hot air volume by pressing When the screen A or screen B shine C F as you set the device is under the setting condition and shining area for C F switch to screen A au...

Page 9: ...A display character SLP diagram 3 8 Conversation between cold air and hot air In normal condition continually press knob twice and then make the hot air be in the state of cold air blow diagram12 Under the cold air condition press knob once recover the hot air working condition 9 Standby Under normal working condition the device keep the current temperature and air volume and cut down heating to t...

Page 10: ...y press SET knob twice to switch to shine C F then press the UP or DOWN knob to adjust temperature Screen B shines SET and the main temperature area shines the setting temperature of soldering station Stopping pressing knob or pressing SET knob confirm and keep settings and quit from this operation diagram17 3 Shortcut keys set storage Under normal working condition hold down POWER knob at the lef...

Page 11: ... SET knob to confirm storage and quit from this calibration diagram 11 5 Standby In normal working condition press POWER key at the right of panel to make the device be standby diagram 2 Make the power off at the same time the soldering station is off and the whole station will off when the temperature is low to 100 C 6 Error Fault indication A When H E is displayed on the screen A there is no tem...

Page 12: ... remove Please follow the following steps for the successful replacement of heating element of soldering station A Cut down power replace the heating element after it is cool B As following diagram unscrew the nut 1 take out the stainless steel cap 2 and iron tip 3 then unscrew the fixed holder 4 desoldering the heating element 5 C Replace the good condition heating element and install it as the c...

Page 13: ...as aware of the possibility of such loss or damage arising is excluded This will not operate to limit or restrict the Group s liability for death or personal injury resulting from its negligence Tenma is the registered trademark of the Group Premier Farnell Limited 2016 b Cleaning Clean the tip regularly with a cleaning sponge as oxides and carbides from the solder and flux can form impurities on ...

Reviews: