TM
TM
Page <20>
V1.0
27/12/19
Newark.com/exclusive-brands
Farnell.com/exclusive-brands
Element14.com/exclusive-brands
F. Continuity Test
Range
Resolution
Overload Protection
Remarks
1Ω
250V rms
•
Open circuit voltage approximate -1.2V.
•
When circuit disconnected with resistance value
> 30Ω, buzzer does not beep.
•
When circuit is in good connection with resistance
•
value ≤70Ω buzzer beeps continuously.
G. Diode Testst
Range
Resolution
Overload Protection
Remarks
10mV
250V rms
•
Open circuit voltage approximate 2.7V.
•
Working current approximate 1mA.
H. Capacitance
Range
Resolution
Accuracy
Overload Protection
6nF
0.001nF
± (2.5%+5)
250V rms
60nF
0.01nF
600nF
0.1nF
± (2%+5)
6μF
0.001μF
60μF
0.01μF
600μF
0.1μF
± (3%+4)
6mF
0.001mF
± (5%+4)
Remarks:
• At 6nF, 60nF and 600nF Range: reading must subtract the test lead open circuit capacitance value.
I. Frequency
Range
Resolution
Accuracy
Overload Protection
6kHz
0.001kHz
± (0.1%+3)
250V rms
60kHz
0.01kHz
600kHz
0.1kHz
6MHz
0.001MHz
60MHz
0.01MHz
Remarks:
• Input scope (a): (DC electric level is zero)
When 10Hz to 1MHz
: 150mV ≤ a ≤ 30V rms
When > 1MHz to 10MHz : 300mV ≤ a ≤ 30V rms
When > 10MHz to 50MHz : 600mV ≤ a ≤ 30V rms
When > 50MHz
: Unspecified