Use the diode test to check diodes, transistors, and other
semiconductor devices. The diode test sends a current
through the semiconductor junction, and then measures
the voltage drop across the junction. A good silicon junction
drops between 0.5V and 0.8V
To test out a diode out of a circuit, connect the Meter as
follows:
1. Insert the red test lead into the Hz V
Ω
terminal
and the black test lead into the COM terminal
2. Set the rotary switch to .
3. For forward voltage drop readings on any semiconductor
component, place the red test lead on the component’s
anode and place the black test lead on the component’s
cathode.
The measured value shows on the display.
l
The open-circuit voltage is around 3V.
l
When diode testing has been completed, disconnect
the connection between the testing leads and the
circuit under test.
Measurement Operation(7)
black red
(figure 7)
Warning
To avoid personal injury, please do not attempt to
input voltages higher than 60V DC or 30V rms AC.
To avoid damage to the Meter or to the devices under
test, disconnect circuit power and discharge all the
high-voltage capacitors before testing for continuity.
To test for continuity, connect the Meter as below:
1. Insert the red test lead into Hz V
Ω
terminal and
the black test lead into the COM terminal.
2. Set the rotary switch to .
3. Connect the test leads across with the object being
measured.
4. The buzzer does not sound if the resistance of a
circuit under test is >100
Ω
The buzzer sounds continuously if the circuit is in
good condition with resistance value 10
Ω
.
The measured value shows on the display and the
unit is
Ω
.
Model 72-7930: OPERATING MANUAL
20
Summary of Contents for 72-7930
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 21: ...Model 72 7930 OPERATING MANUAL 21 To avoid personal injury F ...
Page 23: ...Model 72 7930 OPERATING MANUAL 23 F hFE To avoid personal injury and mA ...
Page 24: ...POWER Model 72 7930 OPERATING MANUAL 24 100 ...
Page 25: ...Model 72 7930 OPERATING MANUAL 25 ...
Page 29: ...Model 72 7930 OPERATING MANUAL 29 100 ...