Please read these instructions carefully before use and retain for future reference.

• 

Please operate according to this manual, otherwise the protection provided by the 

device will be impaired or fail.

• 

Do not point laser directly in your eyes or indirectly off reflective surfaces.

• 

Check  the  condition  before  using.  If  you  find  any  cracking,  breakage,  damage  or 

abnormality, or you consider the device broken, stop using the device immediately

• 

Do not use the Thermometer if it operates abnormally. Protection may be impaired. 
When in doubt, have the Thermometer serviced.

• 

Do not operate the Thermometer around explosive gas, vapour, or dust.

• 

To avoid a burn hazard, remember that highly reflective objects will often result in 

lower than actual temperature measurements.

• 

To avoid damaging the thermometer or the equipment under test protect them from 

the following:

 

EMF (electro-magnetic fields) from arc welders, induction heaters, etc.

 

Static electricity.

 

Thermal shock (caused by large or abrupt ambient temperature changes –  

 

allow 30 minutes for the Thermometer to stabilize before use).

• 

Do not leave the Thermometer on or near objects of high temperature.

• 

Replace the batteries as soon as the low battery indicator appears on the display.

• 

Remove dead batteries from the Thermometer or if it is not going to be used for a 

long time.

• 

Never mix old and new batteries together, or different types of batteries.

• 

Never dispose of batteries in a fire, or attempt to recharge ordinary batteries.

• 

Before replacing the battery, turn off the Thermometer and disconnect all the test 

probes.

• 

To prolong battery life turn off the Thermometer after use.

IMPORTANT SAFETY INFORMATION

WHAT’S INCLUDED

FEATURES

• 

Infrared Thermometer with laser sighting.

• 

9V 6F22 Alkaline Battery (included)

• 

Instruction manual

• 

Single-spot laser sighting.

• 

White backlight.

• 

Synchronous display of the measured maximum and minimum value.

• 

Celsius and Fahrenheit temperature measurement.

• 

Dynamic battery capacity monitoring.

• 

Low voltage indication.

• 

Display screen.

• 

Adjustable emissivity.

• 

Alarm sounder for upper and lower limit.

Summary of Contents for 72-8732

Page 1: ...1 Model 72 8732 Infrared Thermometer ...

Page 2: ...c electricity Thermal shock caused by large or abrupt ambient temperature changes allow 30 minutes for the Thermometer to stabilize before use Do not leave the Thermometer on or near objects of high temperature Replace the batteries as soon as the low battery indicator appears on the display Remove dead batteries from the Thermometer or if it is not going to be used for a long time Never mix old a...

Page 3: ...inimum temperature anytime the display is on The MAX MIN temperatures are constantly calculated and updated while the trigger is pressed After the trigger is released all readings are held for 8 seconds Emissivity setting display Laser on symbol SCAN Active SCAN HOLD Display Hold MAX MIN Maximum or Minimum Value Low Battery symbol Appears when the battery charge is 4 5V Backlight indication o C o ...

Page 4: ...er The Thermometer turns off when no activity is detected for 8 seconds To measure temperature aim the Thermometer at the target pull and hold the trigger Release the trigger to hold a temperature reading To find a hot or cold spot aim the Thermometer outside the target area Then slowly scan across the area with an up and down motion until you locate the hot or cold spot Distance and target spot s...

Page 5: ...ou to adjust the unit s emissivity for the type of surface To adjust values for emissivity see table below 1 Press SET to select emissivity set up icon E on the display will flash The Thermometer steps through emissivity set up o C o F high low limit setting 2 Press to increase the value by 0 01 The maximum value is 1 00 3 Press to decrease the value by 0 01 The minimum value is 0 10 Measure Surfa...

Page 6: ...l start flashing to allow you to allow or disable the high limit audible warning Press SET to enter the low setting MIN will flash on the display Select or to adjust in 0 1 degree increments Hold the adjustment button for a rapid incremental change The sounder indicator will start flashing to allow you to allow or disable the low limit audible warning When the sounder is active an intermittent sou...

Page 7: ...zontal rows of wall from top to bottom or horizontal rows of ceiling from wall to wall Look for greatest deviations from baseline temperature to identify problems This completes the insulation test scan Checking Hydronic radiant heat applications Radiant heat tubes in the floor will normally run parallel to the outside walls Starting at the floor wall juncture scan parallel to the wall while movin...

Page 8: ...95 500ms Distance to Spot 12 1 Emissivity adjustment 0 10 1 00 Laser Sighting Single point laser Power Class 2 Output 1mW wavelength 630 to 670mm Power Supply 6F22 9V Battery Power consumption Over 30hrs alkaline or over 10hrs gp Weight 0 322kg INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL ELECTRONIC EQUIPMENT These symbols indicate that separate collection of Waste Electrical and Elec...