Operating Guidelines:
Manual Operating Frequency Selection
The SMD Rework Station has already the capability of auto selecting the frequency based on the input power. However, in
rare very cases, users may want to manually select the operating frequency. The following procedure will instruct you how to
do this.
Steps:
1. Switch the unit ON (or press “Reset” button, D, from the panel).
2. Press and hold C1 while the banner is scrolling.
3. The display panel, B1, will initially indicate ‘60’ , which means the device is currently operating at 60Hz of frequency.
4. Use buttons C3 and C4 to switch between 50 Hz and 60Hz.
5. Press C2 to confirm. The system will resume automatically.
Temperature Setting and Adjustment
1. While the unit is ON and the Hot Air Gun switch set to “Reworking”, press buttons C1 or C2 from the control panel to increase
or decrease the temperature, respectively.
2. The display panel, B1, will show something like ‘bXXX’ while the temperature is being adjusted.
You will also notice that a red light (“I” from control panel) is blinking from the panel. This is to indicate that the system is trying