Rework Station
Instruction Manual
Changing The Fuse:
• Make sure the equipment is completely isolated from the main power source before changing the fuse.
• The fuse of the main unit is located at the back of the equipment, right above the power plug connector.
• Change the blown fuse by unscrewing the fuse holder.
• Replace only with the same fuse type, size, and rating. Use the table below as reference.
• Keep a spare fuse of the same rating for emergency purpose.
Location
Rating
Size
Rear Panel
3A, 220V
5mm × 20mm
5A, 110V
Spare Parts List:
Number
Name & Specification
10094
Hot air gun heating element
30104S
Plastic handle of hot air gun
S003
Hot air gun complete handle
20932
Hot air gun metal pipe
P002
Diaphragm pump
Warning
All cleaning and/or maintenance should be performed when the equipment
is switched off and completely disconnected from the main power source.
Maintenance: