Basic Troubleshooting Guide:
Solution:
The thermal sensor may be broken and needs to be replaced.
Problem 3: Actual Air Temperature is not Increasing
Description:
Actual temperature reading is not increasing or decreasing based on desired level. The panel will then display a
blinking “OFF” on both sides afterwards.
Solution:
The heating element may be broken and needs to be replaced, or the thermal sensor could be shorted.
Problem 4: Banner or Product Name is Always
Scrolling The Unit is not Usable
Description:
The product name is just always scrolling from the digital panel, rendering the device unusable.
Solution:
Try to press “Reset” from the panel. Note that resetting the device will also reset all previously defined configurations.
Problem 5:
Air Pressure Level is Significantly Low no Matter How High the Airflow Level is Calibrated
Case 1:
Check the mains voltage (AC power source). If the voltage level falls significantly low, about 1520% lower than the
standard, there will also be a noticeable drop in the air pressure level.
Solution:
Please refer to your local power service provider.
Case 2:
The microcontroller might have detected the operating frequency incorrectly. The user will notice that airflow level is
weaker compared to the displayed value.
Solution:
Try to press the “Reset” button on the panel and let the device re detect the proper operating frequency. Note that
resetting the device will also reset all previously defined configurations.