Rework Station
Instruction Manual
Basic Troubleshooting Guide:
Problem 6:
The Unit iss Very Noisy
Solution:
Make sure the screw has been removed from the center of the base of main unit. Remove if otherwise.
Problem 7:
The Unit is Vibrating too Much Check if the 4 screws that hold the pump in place are properly and tightly connected.
Unplug the system from the main power source before opening the case to check the internal settings.
Problem 8:
Display and Other Device Operation Issues
Solution:
Try to press the “Reset” button on the device. Note that resetting the device will also reset all previously defined
configurations.
Problem 9:
For SS-952 Only; Air Pressure Drops When Using the Suction Pen
Description:
The Air pressure drops when using the suction pen and does not recover to its previous height in the air gauge.
Solution:
Decrease the air pressure level, set air pressure level at about 80.
Note:
(for SS-952 only)
Air pressure level may drop a little when the suction pen is picking up ICs. The air pressure level gauge should revert back to
its previous state when the IC is released. Blockages in the suction pen’s tube and nozzle may cause the air pressure to drop.
Clean the air passage for maximum air pressure capacity regularly.