Operating Guidelines:
Sleep Mode Timer SetUp
1. Switch the unit ON (or press “Reset” button, D, from the panel).
2. Press and hold C3 while the banner is scrolling.
3. Display panel, B2, will initially indicate ‘L05’, which means the device will switch to sleep mode after 5 minutes (default) of
idle time and if the nozzle is docked on the handle for the duration of time.
4. Adjust the time before sleep by pressing buttons C1 or C2.
5. Press C4 to confirm.
6. The device will start counting down when the hot air gun is docked on the handle. Once countdown is finished and the hot
air gun still docked, the device will automatically blow air (at room temperature) to bring down temperature to 90°C. The panel
will then display the following after reaching the safe temperature level and to indicate that the device is now in sleep mode.
Notes:
• Time is configurable from 1 to 20 minutes (default 5 minutes).
• The device has a switch located at the handle (cradle), which activates the countdown before the system goes to sleep.
• Once the hot air gun is released from the handle during sleep mode, the unit will automatically switch back to previous
working temperature and airflow level parameters.