TM-901N/TM-902/TM-903

 

19 

 

 

Shutoff Rate Power :

1uA

 

 

Operate Maximum Power :

20mA

 

 

Operating temperature and humidity : 

5

to 40

,below 80% RH.

 

 

Storage temperature and humidity :   

-10

 to 60

, below 70%.

 

 

Dimensions : 

156(L)*73(W)*35(H) mm.

 

 

Weight :

 About 170g. 

 

Accessories : 

User’s manual x1, 1.5V 

AAA battery x6, CAT5 STP Cable x1, 
remote ID(1) x1

 

 

Summary of Contents for TM-901N

Page 1: ...Multi Media Cable Tester User Manual TM 901N TM 902 TM 903 TENMARS ELECTRONICS CO LTD HB2TM9020010 ...

Page 2: ......

Page 3: ... 7 Split Pair 8 8 Length measures 9 9 SIGNALTONE measures TM 903 10 10 Using Multiple Remote ID Locators 11 11 Auto power on and off setting mode 12 12 Backlight on or off setting mode 13 13 Changing Memory Number Default Category Types UTP STP Calibrating Length Measurements Value Parameter Options 14 14 Checking the LCD and Software Version 16 15 Battery Replacement 17 16 Options and Accessories...

Page 4: ...while measuring z Do not operate the meter under the environment with explosive gas material combustible gas material steam or filled with dust z In order to avoid reading incorrect data please replace the battery immediately when the symbol appears on the LCD z In order to avoid the damage caused by contamination or static electricity do not touch the circuit board before you take any adequate ac...

Page 5: ...3 The verifier does the following z Detects opens shorts miswires and split pairs on twisted pair cabling z Displays graph wiremap opens shorts miswires split pairs and the remote ID number all on one screen z Identify remote ID number only one pair z Measures length z Using multiple remote ID up to 8 locators z Low battery detector z Auto backlight z Auto power off ...

Page 6: ...3 3 4 Display Features 1 Displays graph wiremap opens shorts miswires split pairs 2 Displays Length and Unit 3 Lower battery indication 4 Enter the SETUP mode symbol 5 Result displays Pass split 6 Displays remote ID number ...

Page 7: ...ting Key and Unit select Key 4 Test Key and Enter Key 5 Setup function left Key 6 Length and wiremap and signal tone function key 7 RJ 45 connector socket 8 F Connector TM 903 9 RJ 11 connector socket TM 903 10 Remote ID locator 11 RJ 45 connector socket of remote ID locator 12 Tilt stand 13 Battery cover ...

Page 8: ...air Cabling 1 Connect the meter and remote ID locator to the cabling as shown in Figures 2 Press the key to power on TM 902 903 3 Press key to measures wiremap and Remote ID Locators detect 4 Display show some testing option as shown in Figures ...

Page 9: ...01N TM 902 TM 903 6 7 Twisted Pair Test Results The following figures show typical test results for twisted pair cabling Any error occurs will show symbol on LCD Opens Figure shows an open pair wire 4 and 5 ...

Page 10: ...rts Figure shows tow short between wires 3 4 and 5 another 1 and 8 When shorted occur the verifier maybe not show open and miswires Miswires Figure shows that wires 3 and 4 are crossed The pin numbers order to indicate the fault ...

Page 11: ...show SPLIT indicate In a split pair continuity from end to end is correct but is made with wires from different pairs Split pairs cause excessive crosstalk that interferes with network operation The spilt pair detects of cable must be at least 5 meter 15ft in length If open short and miswires anyone occur the spilt pair detects will don t work ...

Page 12: ...ures 1 Press the key to power on 2 Press the L W key TM 901N TM 902 or key TM 903 to switch to Length TM 903 3 Press and Key to select show length pairs 1 4 4 In the display length Press the key to changing the length units shown in Figure ...

Page 13: ...n default continuity LCD display C 5 If you want to changing press the Key to select continuity LCD display C to changing one shot LCD display F you can selection numbers 1 8 6 Press the key to enable or disable out signal tone is cable tracing function Toner is cable tracing function that assists in tracking cables hidden in walls Ceilings floors or patch panels by generating four distinct multi ...

Page 14: ...cable 10 Using Multiple Remote ID Locators Using multiple remote ID locators helps you identify multiple network cable connections as shown in Figure The display in Figure shows that the verifier is connected to the cable terminated with remote ID locator number 3 ...

Page 15: ... 1 Press the key to power on 2 Press the key for more than 2 Second to enter Setting mode into setting mode 3 Press the key again to auto power on or off setting 4 Press the or key to change ON or OFF 5 Press the key to enter and exit setting mode shown in Figure ...

Page 16: ...the key for more than 2 Second to enter Setting mode into setting mode Press the key setting to auto power on or off setting Press the key to backlight set Press the key again to backlight setting mod Press the key to change ON or OFF Press the key to enter and exit setting mode shown in Figure ...

Page 17: ...tegory and length to acquire measurements value parameter 1 Press the key to power on 2 Press the key more than 2 second to and setting mode 3 Press the key setting to auto power on or off setting Press the key to backlight set Press and key to select number zero from No 0 9 Press key again to setting flashes number Press and key to select number zero from No 0 9 Press key to enter exit setting mo...

Page 18: ...flashes cable type 6 Press key to select UTP or STP Press key to enter exit setting mode shown in Figure 7 Press the key more than 2 second to and setting mode Press the key again to select setting flashes calibrating length measurements value parameter 8 Press and key to select known length measurements value parameter ...

Page 19: ...903 16 9 Press key to enter and exit setting mode shown in Figure 14 Checking the LCD and Software Version In the shutoff mode Press and hold key again press the key to turn on meter and LCD will keep all dark continued ...

Page 20: ...stalled in the case to power the meter 16 Options and Accessories Consumers can order options and accessories as follows Remote ID Locator Kit numbers 2 8 17 End of life Caution this symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal WARNING If the symbol appears on the LCD please replace the battery immediately ...

Page 21: ...est voice cable RJ11 TM 903 and video coax cable F connenector TM 903 Wiremap test Detects opens shorts miswires split pairs Length test Range up to 255 m 836 ft Resolution 0 1 m ft Unit meter and foot Typical accuracy 10 1 0m 3 ft Display 58mm L x45mm W Monochrome LCD with backlight Battery 1 5Vx6 batteries LR03 SIZE AAA 1 5V Battery Lift Approx continuous testing 200 times ...

Page 22: ...e Maximum Power 20mA Operating temperature and humidity 5 to 40 below 80 RH Storage temperature and humidity 10 to 60 below 70 Dimensions 156 L 73 W 35 H mm Weight About 170g Accessories User s manual x1 1 5V AAA battery x6 CAT5 STP Cable x1 remote ID 1 x1 ...

Page 23: ......

Page 24: ...eter EMF meter UV Light meter RF meter Hot wire Anemometer CO meter Anemometer Lan cable tester CO2 meter Solar power meter Radiation meter Clamp meter Multimeter Phase Rotation test Digital Insulation tester Our products of high quality are selling well all over the world TENMARS ELECTRONICS CO LTD 6F 586 RUI GUANG ROAD NEIHU TAIPEI 114 TAIWAN E mail service tenmars com http www tenmars com ...

Reviews: