MAINTENANCE
5700XP 331533 (3--08)
64
REMOVING OR REPLACING THE SCRUB
HEAD
The scrub heads are available in two brush types,
and three widths. The scrub heads are
interchangeable when the scrub brush motor
circuit breakers, installed in the operator console,
match the circuit breakers needed as shown in
the following chart:
SCRUB HEAD/CIRCUIT BREAKERS
Scrub head
Disk
HD Disk Cylindrical
Model 700
700 mm
(28 in)
20 A
--
20 A
Model 800
800 mm
(32 in)
20 A
35 A
20 A
Model 900
900 mm
(36 in)
--
35 A
20 A
NOTE: To interchange the model 800 or the
model 900 heavy duty disk head with one of the
other available scrub heads, you must change the
scrub brush motor circuit breakers in the operator
console. Interchanging the scrub heads without
changing the scrub brush motor circuit breakers
will cause the scrub brush motors or circuit
breakers to fail.
NOTE: When you change to a different width
scrub head, be sure to install the appropriate
width squeegee and machine front cover.
1. Lower the scrub head.
2. Turn the machine power off.
FOR SAFETY: Before leaving or
servicing machine, stop on level
surface, and turn off machine.
3. Remove the machine front cover.