OPERATION
6500 330270 (9--01)
38
CIRCUIT BREAKERS
(For machines below serial number 020000)
The circuit breakers are resettable electrical
circuit protection devices. Their design stops the
flow of current in the event of a circuit overload.
Once a circuit breaker is tripped, it must be reset
manually. Press the reset button after the breaker
has cooled down.
If the overload that caused the circuit breaker to
trip is still there, the circuit breaker will continue to
stop current flow until the problem is corrected.
All the circuit breakers are located in the operator
compartment except CB--10. It is located in the
cab control panel.
The chart lists the circuit breakers and the
electrical components they protect.
Circuit Breaker
Rating Circuit Protected
CB-1
15 A
Engine and throttle
CB-2
15 A
Vacuum fan, filter
shaker
CB-3
15 A
Operating lights
CB-4
15 A
Hazard light, back-
up alarm
CB-5
15 A
Horn
CB-6
2.5 A
Instrument panel
CB-7
15 A
Heater/defrost,
windshield wiper
CB-8
15 A
Turn Signals
CB-9
15 A
Auxiliary side brush
CB-10
15 A
Cab Pressurizer
07806