T12 Service Information 9009917 (12-12)
4-41
TROUbLESHOOTING
Machine Failed to Power Up
SteP
action
value(S)
yeS
no
1
•
key in Start position
•
Test the total battery voltage using a voltmeter
•
Is the total battery voltage greater than 30 vdC?
Go to Step #2
recharge
batteries and
Test power-up
Circuit opera-
tion
2
•
key off
•
firmly press circuit breaker #2 to reset
•
Is circuit breaker #2 tripped?
reset and Test
power-up Cir-
cuit operation
Go to Step #3
3
•
key off
•
firmly press circuit breaker #3 to reset
•
Is circuit breaker #3 tripped?
reset and Test
power-up Cir-
cuit operation
Go to Step #4
4
•
key off
•
firmly press circuit breaker #1 to reset
•
Is circuit breaker #1 tripped?
reset and Test
power-up Cir-
cuit operation
Go to Step #5
5
•
Cycle key switch from Start to on position
•
Test voltage applied to the power-up subsystem as
shown on the electrical schematic
•
are the electrical circuits operating as shown on the
electrical schematic?
Go back to
Step #1
Identify volt-
age drop
Location and
repair or re-
place neces-
sary Compo-
nents
Terms:
vdC = dC voltage
Summary of Contents for EC-H2O T12