5-36
T12 Service Information 9009917 (12-12)
SERVICE
TESTING VACUUM FAN
1 . key off . disconnect vacuum fan from wire harness .
2 . key off . Inspect carbon brushes . replace carbon
brushes if they are shorter than 10mm (0 .375 in) .
3 . apply battery voltage to the vacuum fan(s) using
fuse-protected jumper leads as shown below . The fan
should turn on . replace the vacuum fan if it fails to
turn on .
VFM003
+
-
+
-
+
-
+
-
+
-
+
-
6 Volt
6 Volt
6 Volt
6 Volt
6 Volt
6 Volt
25 Amp
Fuse
1
2
4 . reconnect vacuum fan(s) to wire harness . See “manual
mode” in the TroubLeShooTInG section . activate
the vacuum fan in manual mode . The amperage
displayed should be approximately 14-20 amps (avg .
16 amps)
VFM004
M04: Vac Fan
00% XX.XA
for Safety: before leaving or servicing machine, stop
on level surface, turn off machine and remove key .
for Safety: When servicing machine, disconnect bat-
tery connection before working on machine .