3-38
T12 Service Information 9009917 (12-12)
MAINTENANCE
STORAGE INFORMATION
The following steps should be taken when storing
the machine for extended periods of time.
1. Charge the batteries before storing machine
to prolong the life of the batteries.
2. Thoroughly drain and rinse the solution and
recovery tanks.
3. Store the machine in a dry area with the
squeegee and scrub head in the up position.
ATTENTION: Do not expose machine to rain,
store indoors.
4. Open the recovery tank cover to promote air
circulation.
5. If storing machine in freezing temperatures,
proceed to
FREEZE PROTECTION
.
NOTE: To prevent potential machine damage
store machine in a rodent and insect free
environment.
FREEZE PROTECTION
FOR SAFETY: Before leaving or servicing
machine, stop on level surface and turn off
machine.
1. Completely drain the solution tank and
recovery tank.
2. Pour 7.6 L (2 gal) of Propylene Glycol Based /
Recreational Vehicle (RV) antifreeze into the
solution tank.
3. Turn on the machine.