USE and CARE Guide
2401/2601 Speed Scrub
Disc Model
613997 Rev 00 (05–03)
WARNING:
Failure to follow these warnings may result in personal injury, electrocution, electrical shock, fire
or explosion: Do not use flammable liquids or operate machine in or near flammable liquids, vapors or
combustible dusts. Do not pick up flammable materials or reactive metals. Keep sparks and open flame away.
Keep battery hood open when charging. Disconnect battery cables before servicing machine.
DAILY:
BEFORE EACH USE
1.
Sweep and dust
mop floor before
scrubbing.
6.
Make sure recovery
tank is empty and the
float screen is installed
and clean.
2.
Check battery
meter charge level.
7.
FaST
Model –
Check the FaST
PAK
agent level. Replace
PAK as needed.
3.
Check all switches
to make sure they
operate properly.
8.
FaST
Model –
Check that the supply
hose is properly con-
nected to FaST
PAK.
4.
Check condition of
scrubbing pads.
Replace if worn.
9.
For Conventional
Scrubbing Only – Fill
solution tank with water
(140
5
max.) and add
5.
Clean squeegee
and check condition of
wiping edge. Rotate
blade if worn.
approved cleaning
agents.
FaST
Model – USE
CLEAR COOL WATER
ONLY. DO NOT add
cleaning agents into the
solution tank or damage
may result.
DAILY:
AFTER EACH USE
1.
Drain and rinse out
recovery tank.
6.
Clean machine with
an all purpose cleaner
and damp cloth.
2.
Remove and rinse
off float screen filter.
7.
FaST
Model –
Connect FaST
PAK
supply hose to storing
plug when not in use.
3.
Drain and rinse out
solution tank.
8.
Recharge batteries
ONLY if machine is used
30 minutes or more.
4.
Remove pads/
brushes and clean.
9.
Check battery fluid
level before charging.
5.
Wipe clean the
squeegee blades.
The fluid level (A)
should cover battery
plates (B) by 1/4”. Add
distilled water if
needed.
A
B
MONTHLY:
Refer to Operator’s Manual for further details.
1.
Remove and clean
the solution tank filter
(clear bowl). Empty
tank before removing.
2.
Lubricate caster
fittings with a water
resistant grease.
3.
Clean battery tops
and terminals. Use a
strong mixture of
baking soda and water.
4.
Flush the solution
system with an acetic
acid solution.
5.
FaST
Model –
Remove and clean the
air pump filter every
250 hours.
ATTENTION: FOR MACHINE REPAIRS, CONTACT AN AUTHORIZED SERVICE CENTER.