EN
English
20
Tennant T300e (07- 2022)
SQUEEGEE BLADE REPLACEMENT
FOR SAFETY: Before leaving or servicing machine,
stop on level surface, turn off machine and remove
key.
Each squeegee blade has four wiping edges. When the
blades become worn, simply rotate the blades
end-for-end or top-to-bottom for a new wiping edge.
Replace blade if all four edges are worn.
1. Remove the squeegee assembly from the machine.
2. Fully loosen the two outside knobs on squeegee
assembly. This will separate the spring loaded
blade retainer from squeegee frame (Figure 43). To
loosen the knobs quickly, squeeze the blade
retainer and squeegee frame together.
FIG. 43
3. Remove worn blade(s) from the blade retainer
(Figure 44).
FIG. 44
4. Rotate the rear blade to a new wiping edge (Figure
45). Make sure to align the slots in the blade with
retainer tabs.
FIG. 45
5. Squeeze the squeegee frame and blade retainer
together and re-tighten the two outside knobs
(Figure 46).
FIG. 46