66
T380AMR 9020999 (08-2020)
MAINTENANCE
CHECKING THE ELECTROLYTE LEVEL
The
fl
ooded (wet) lead-acid batteries require
routine watering as described below. Check the
battery electrolyte level weekly.
NOTE:
Do Not
check the electrolyte level if the
machine is equipped with a battery watering
system.
08247
FOR SAFETY: When servicing machine, keep
all metal objects off batteries. Avoid contact
with battery acid.
The electrolyte level should be slightly above the
battery plates as shown before charging. Add
distilled water if low. DO NOT OVERFILL. The
electrolyte will expand and may over
fl
ow when
charging. After charging, distilled water can be
added up to about 3 mm (0.12 in) below the sight
tubes.
Before Charging
After Charging
NOTE: Make sure the battery caps are in place
while charging. There may be a sulfur smell after
charging batteries. This is normal.
CHECKING CONNECTIONS / CLEANING
After every 200 hours of use check for loose
battery connections and clean the surface of the
batteries, including terminals and cable clamps,
with a strong solution of baking soda and water.
Replace any worn or damaged wires. Do not
remove battery caps when cleaning batteries.