CIRCUIT BREAKERS AND FUSES
CIRCUIT BREAKERS
Circuit breakers are resettable electrical circuit
protection devices that stop the
fl
ow of current
in the event of a circuit overload. Once a circuit
breaker is tripped, allow breaker to cool and
then press the reset button to manually reset the
breaker.
If the overload that caused the circuit breaker to
trip is still there, the circuit breaker will continue to
stop current
fl
ow until the problem is corrected.
The circuit breakers are located inside the battery
compartment next to the hour meter.
The chart shows the circuit breakers and the
electrical components they protect.
Circuit
Breaker
Rating
Circuit Protected
CB1
4 A
Instrument panel - power
CB2
4 A
Accessories
CB3
20 A
AMR system
CB4
10 A
Brain module
FUSES
The fuse is a one-time protection device designed
to stop the
fl
ow of current in the event of a circuit
overload. The 100 A fuse is located in the electrical
box near the scrub head actuator. The fuse
protects the machine controller.
NOTE: Always replace the fuse with a fuse of the
same amperage.
ELECTRIC MOTORS
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off
machine, and remove key.
Replace or check the motor carbon brushes as
indicated. Contact trained personnel to check or
replace carbon brushes.
Carbon Brush Replacement/
Check
Hours
Vacuum motor (replace)
750
Propel motor (check)
500
Brush motor (replace)
1250