74
T380AMR 9020999 (08-2020)
MAINTENANCE
ec-H2O
SYSTEM
ec-H2O
WATER CONDITIONING CARTRIDGE
REPLACEMENT
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off
machine, and remove key.
The water conditioning cartridge is required to
be replaced when it reaches its maximum water
usage or expiration time of when the cartridge was
activated, which ever comes
fi
rst. The
ec-H2O
system indicator light will blink green/red when it is
time to replace cartridge.
Depending on machine usage, on average, a
new cartridge can last anywhere from 12 months
for heavy machine usage to 24 months for light
machine usage.
NOTE: During
fi
rst time use and after replacing the
water conditioning cartridge, the ec-H2O system
will automatically override the selected solution
fl
ow rate for up to 75 minutes.
1. Lift the recovery tank/seat open and engage
prop arm to access the ec-H2O cartridge.
2. Disconnect the two hose connectors from
cartridge by pressing the gray collars inward
and pulling the connectors outward. Lift
cartridge to remove.
3. Fill in the installation date on the new cartridge
label.
4. Install the new cartridge and reconnect the two
hoses. Make sure the hose connectors are
fully inserted into new cartridge.