MAINTENANCE
JACKING UP THE MACHINE
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off
machine, and remove key.
Empty the recovery and solution tanks before
jacking the machine.
Remove the front perimeter guard from the front
perimeter guard brackets located at the front of
the machine before jacking up the front end of the
machine.
The jacking location at the front of the machine is
located on the back of the LIDAR bracket.
Do Not
position the jack or jack stand at the front of the
LIDAR bracket.
9
Rear jacking locations are located on both sides of
the machine at the axles.
FOR SAFETY: When servicing machine, block
machine tires before jacking machine up. Use
a hoist or jack that will support the weight of
the machine. Jack machine up at designated
locations only. Block machine up with jack
stands.