PLDC04453
REVISION 00
December 23, 2020
TECHNICAL OFFICE
Stavale
1
Move the machine to the tank draining area, and empty the solution tank and the dirty water tank.
2
Move the machine onto flat and dry flooring.
3
Press the emergency switch to switch off all the functions.
4
Lower the brush head using the pedal control.
5
Disconnect the batteries from the machine's main wiring.
6
Remove the brush head cover, unscrewing the four screw.
7
Identify the two screw
A
that secures the metal band on the brush motor.
8
Unscrew the screw
A
and remove the metal band on the brush motor
A1.2 Replacing the brush motor carbon brushes
Dismantling
A
Fig. 6
Fig. 7
5 of 73