PLDC04453
REVISION 00
December 23, 2020
TECHNICAL OFFICE
Stavale
7
Switch the machine on using the brush button
B
.
8
Press and hold the brush button
B
and the suction motor button
C
together for around 5 seconds,
and in any case until the display shows the type of batteries set.
9
Use the button
C
to select the type of battery, between GEL and ACID.
Setting on "Pad Assist" versions without drive
B
Fig. 73
C
B
Fig. 74
C
C
Fig. 75
35 of 73