PLDC04453
REVISION 00
December 23, 2020
TECHNICAL OFFICE
Stavale
6
To remove the contact
E
from the "mushroom" head or emergency button, use a flat-head screwdriver
to slightly lift the tab until it detaches from the support. Being an ON/OFF switch, when reassembling,
its orientation is not important.
7
Detach the two wires (orange and purple) connected to the forwards-reverse switch
F
, when
reassembling, being an ON/OFF contact, the position of the wires is not important.
8
Disconnect the four-pin connector
G
dedicated to traction motor taking special care.
Assembly is orientation-sensitive by the locking connector fitted on the instrument panel board.
1
To assemble the new instrument panel board, repeat the disassembly operations in reverse.
Reassembly
E
F
Fig. 81
G
38 of 73