PLDC04453
REVISION 00
December 23, 2020
TECHNICAL OFFICE
Stavale
1
Move the machine to the tank draining area, and empty the solution tank and the dirty water tank.
2
Move the machine onto flat and dry flooring.
3
Press the emergency key switch until it is held in the bottom position.
4
Remove the squeegee from the mount.
5
Disconnect the batteries from the wiring and each other and remove them from the battery compartment.
6
Tilt the machine over until it rests on the left side.
7
It is recommended to lay something soft between the floor and the side, to avoid damaging the side.
8
Unscrew the two screws and remove the two drive wheels from the drive motor axle.
9
Electrically disconnect the drive motor, both the thermal cutout
A
and the power supply
B
.
C2.3 Replacing the complete drive unit (motor + reduction unit)
Dismantling
Fig. 91
B
A
B
B
44 of 73