116
T500 9015504 01-2018
SERVICE
3. Loosen the carbon brush mounting hardware.
4. Lift up to release and remove carbon brushes.
NOTE: Carbon brushes should be replaced as sets.
INSTALLING CARBON BRUSHES
FOR SAFETY: Before leaving or servicing machine,
stop on level surface, turn off machine, set parking
brake, and remove key.
1. Inspect carbon brushes. Replace carbon brushes if
they are stuck or are less than 10 mm (0.375 in) in
length.
NOTE: Carbon brushes should be replaced as sets.
2. Use a stone to clean the commutator and then use
compressed air to clean any dust from inside the
motor.
3. Reinstall the vacuum fan onto the machine. See
REMOVING / INSTALLING THE VACUUM FAN in
this section of manual.