44
T500 9015504 01-2018
TROUBLESHOOTING
BDI (Battery
Discharge
Indicator)
☼
= Flashing
Pro-Panel
LCD
Faults
(Option)
Fault Condition
Reason
Correction
☼
☼
☼
☼
●
0x0102
Scrub Motor 1 Voltage
/ Power Loss
1. Scrub Controller board not detecting
power.
2. Intermittent control board power
loss.
Inline fuse may be blown
or bad. Replace inline fuse.
Check wiring.
0x0112
Scrub Motor 2 Voltage
/ Power Loss
1. Scrub Controller board not detecting
power.
2. Intermittent control board power
loss.
Check wiring and/or inline
fuse for bad connection.
●
☼
☼
●
☼
0x0208
Actuator stalled
1. Object/debris blocking actuator.
Clear blockage from actuator.
●
☼
●
●
☼
0x0301
Valve Open Warning
1. Wiring, connector or control board
issue with the valve.
2. Scrub Controller board connector J8
pin 2 disconnected.
Check connections/wiring.
●
☼
●
☼
☼
0x0303
Valve Over Current
Fault
1. Valve connections shorted.
2. Faulty valve.
3. Scrub Controller board damaged.
Check connections/wiring.
Check valve.
●
●
☼
●
●
0x0501
Vacuum Motor Open
Warning
1. Wiring, connector or control board
issue on the vacuum.
2. J10 connector on scrub controller
board unplugged.
3. Scrub controller board power dis-
connected.
4. Scrub controller inline power fuse
defective/blown.
Check connections/wiring.
Board gets power from key
switch and battery. Replace
defective/blown inline power
fuse.
●
●
☼
●
☼
0x0601
Detergent
Pump
Open Warning
1. Wiring, connector, or control board
issue on detergent pump.
2. Detergent pot connector unplugged.
3. Detergent pot connector Pin 5 or
6 disconnected.
4. Scrub Controller board J8 pin 1 or 6
disconnected.
Check connections/wiring.
●
●
☼
☼
●
0x1005
Scrub Undercurrent
Warning
1. Motor current is too low. Machine is
driving head down to Max Down Force
switch.
2. Applies to disk and cylindrical head
machines.
3. Pad is not aggressive enough for
fl oor surface. Floor surface is too slip-
pery.
4. There are no brushes on machine.
5. The pad driver is broken and is not
driving brushes.
6. Something preventing pads from
contacting fl oor.
Ensure brushes/pads are
on machine and they are
contacting fl oor surface. Try
a more aggressive brush/pad
combination.
●
●
☼
☼
☼
0x0901
Propel Motor Open
Warning
1. Motor on propel I-Drive is not con-
nected.
☼
●
●
●
☼
0x0900
Propel Generic Fault
1. Generic i-Drive fault.
2. Large white i-Drive connector pin 2,
8, or 9 disconnected.
3. User Interface speed pot connector
unplugged.
Power cycle machine. Check
connections/wiring.
Summary of Contents for t500
Page 5: ...5 T500 9015504 01 2018 CONTENTS ...
Page 55: ...55 T500 9015504 01 2018 TROUBLESHOOTING ...
Page 89: ...89 T500 9015504 01 2018 SERVICE 9 Cycle the key switch to save selections ...
Page 111: ...111 T500 9015504 01 2018 SERVICE ...
Page 117: ...117 T500 9015504 01 2018 SERVICE ...
Page 146: ...146 T500 9015504 01 2018 SERVICE ...