47
T500 9015504 01-2018
TROUBLESHOOTING
BDI (Battery
Discharge
Indicator)
☼
= Flashing
Pro-Panel
LCD
Faults
(Option)
Fault Condition
Reason
Correction
☼
●
●
☼
☼
0x0109
Scrub Motor 1 Over
Heat Fault
1. Motor is drawing too much current
and is overheating.
Inspect scrub brushes to see
if they are completely worn. If
scrub brushes are not worn,
motor is defective. Replace
scrub motor.
☼
☼
●
☼
☼
0x0113
Scrub Motor 2 Over
Current Fault
1. Current draw higher than expected.
2. Some higher current draw than
hardware design limit.
Verify fl oor, pad, and down
pressure combination are ap-
propriate for machine.
Check actuator.
0x0114
Scrub Motor 2 Over
Current 1 Fault
1. Current draw higher than expected.
Verify fl oor, pad, and down
pressure combination are ap-
propriate for machine.
Check actuator.
0x0115
Scrub Motor 2 Over
Current 2 Fault
1. Current draw higher than expected.
Verify fl oor, pad, and down
pressure combination are ap-
propriate for machine.
Check actuator.
0x0116
Scrub Motor 2 Short
Fault
1. Shorted load condition.
2. Some higher current draw than
hardware design limit.
Check wire harness and
repair as needed.
0x0119
Scrub Motor 2 Over
Heat Fault
1. Motor is drawing too much current
and is overheating.
Inspect scrub brushes to see
if they are completely worn.
If scrub brushes are not worn
and head is not orbital head,
motor is defective. Replace
scrub motor. If head is orbital,
eccentric or motor might be
bad.
☼
●
☼
●
☼
0x0902
Propel High Throttle
Fault
1. Bail is activated before turning on
machine.
2. Bail did not release to full rest posi-
tion due to obstruction behind it.
Release bail or bail obstruc-
tion before turning on ma-
chine.
☼
●
☼
☼
●
0x0107
Scrub Motor 1 FET
Fault
1. Control board problem.
2. Power/battery issue on startup.
Replace control board. FET
detection includes motor,
actuator, detergent pump,
vacuum and battery watering
pump.
0x0117
Scrub Motor 2 FET
Fault
1. Control board problem.
2. Power/battery issue on startup.
Replace control board. FET
detection includes motor,
actuator, detergent pump,
vacuum and battery watering
pump.
0x0207
Actuator FET Fault
1. Control board problem.
2. Power/battery issue on startup.
Replace control board. FET
detection includes motor,
actuator, detergent pump,
vacuum and battery watering
pump.
0x0307
Valve FET Fault
1. Control board problem.
2. Power/battery issue on startup.
Replace control board. FET
detection includes motor,
actuator, detergent pump,
vacuum and battery watering
pump.
Summary of Contents for t500
Page 5: ...5 T500 9015504 01 2018 CONTENTS ...
Page 55: ...55 T500 9015504 01 2018 TROUBLESHOOTING ...
Page 89: ...89 T500 9015504 01 2018 SERVICE 9 Cycle the key switch to save selections ...
Page 111: ...111 T500 9015504 01 2018 SERVICE ...
Page 117: ...117 T500 9015504 01 2018 SERVICE ...
Page 146: ...146 T500 9015504 01 2018 SERVICE ...