53
T500 9015504 01-2018
TROUBLESHOOTING
Icon
Code
Fault Condition
Reason
Correction
0x0727
ec-H2O Cell FET
Faults
1. Control board problem.
2. Power/battery issue on startup.
Replace control board. FET detec-
tion includes motor, actuator, de-
tergent pump, vacuum and battery
watering pump.
0x0728
ec-H2O Cell Over
Regulation
1. Control board problem.
0x0729
ec-H2O Cell Under
Regulation
1. Control board problem.
0x072A
ec-H2O Cell Elec-
trode Fault
1. Cell current is operating below
allowed operating condition.
See NanoClean troubleshooting
guide. Replace plumbing half of
ec-H2O module.
0x0741
ec-H2O WCM Pump
Open Warning
1. Wiring, connector or control
board issue on the ec-H2O pump.
Check Water Conditioning Mod-
ule micro pump is connected to
machine harness and verify pump
is good.
0x0746
ec-H2O WCM Pump
Short Warning
1. Shorted load condition.
2. Some higher current draw than
hardware design limit.
Check harness and verify Water
Conditioning Module micro pump
is good.
0x0747
ec-H2O WCM Pump
FET Fault
1. Control board problem.
2. Power/battery issue on startup.
Replace control board. FET detec-
tion includes motor, actuator, de-
tergent pump, vacuum and battery
watering pump.
Summary of Contents for t500
Page 5: ...5 T500 9015504 01 2018 CONTENTS ...
Page 55: ...55 T500 9015504 01 2018 TROUBLESHOOTING ...
Page 89: ...89 T500 9015504 01 2018 SERVICE 9 Cycle the key switch to save selections ...
Page 111: ...111 T500 9015504 01 2018 SERVICE ...
Page 117: ...117 T500 9015504 01 2018 SERVICE ...
Page 146: ...146 T500 9015504 01 2018 SERVICE ...