72
T500 9015504 01-2018
TROUBLESHOOTING
SOLUTION CONTROL ON (ec-H2O)
Batt
er
y (+)
C1 Capacitor (0.01μf )
+
-
ec-H2O
Pump
Water Conditioning
Module Pump
Com
N.C.
N.O.
N.C. Opens @
6 PSI +/- 2 PSI = Fault
4EB/YEL
4EA/YEL
3EA/ORA
3EB/ORA
CB2
10A
46/BLU
67/PUR
66/BLU
13/BLK
13/BLK
13/BLK
13/BLK
13/BLK
2/BRN
52/BRN
CAN-/GRN
CAN+/YEL
60/TAN
9EA/WHT
Flush Switch
13EA/BLK
14/YEL
1/RED
6/BLU
Twisted Pair
MTR
30
87
Aux Contactor Relay
ec-H2O Mode Switch
Key S
wit
ch
J6-1
CB - Status
ec-H2O NanoClean
Module
J12-11 VCC_1
GND J12-5
GND J12-6
CAN (+) J12-2
CAN (-) J12-3
PRESSURE IN J12-9
(FLUSH GND)
J11-1
(FLUSH SW)
J11-2
J12-12 VCC_2
J12-13 WCM
PUMP
J12-14 WCM
PUMP
J12-8 PUMP
J11-4 (CELL_A1)
J11-5 (CELL_A2)
J11-3 (CELL_B1)
J11-6 (CELL_B2)
MTR
Batt
er
y (-)
E-CELL
J7-3 Interface
Module
Low-6 Volts
Med-10 Volts
Hi-13 Volts
Solution
Control
(ec-H2O)
Enabled
• Head Lowered -
One Step Button
• Solution Control ON
• ecH2O Switch ON
• Fwd/Rev Throttle
Command or Bail activated
• Head Raised -
One Step Button
• Solution Control OFF
• ecH2O Switch OFF
•
Neutral - Ready State or
bail released
• Low Battery Voltage
• ecH2O System Fault
• Battery Charger ON
Interlock
Disabled
Operational Matrix:
46/BLU
46/BL
U
46/BLU
46/BLU
Battery Po
Battery Negative -
D-1
M1A
86
85
M1B
Summary of Contents for t500
Page 5: ...5 T500 9015504 01 2018 CONTENTS ...
Page 55: ...55 T500 9015504 01 2018 TROUBLESHOOTING ...
Page 89: ...89 T500 9015504 01 2018 SERVICE 9 Cycle the key switch to save selections ...
Page 111: ...111 T500 9015504 01 2018 SERVICE ...
Page 117: ...117 T500 9015504 01 2018 SERVICE ...
Page 146: ...146 T500 9015504 01 2018 SERVICE ...