96
T500 9015504 01-2018
SERVICE
CHANGING THE OFF-BOARD BATTERY CHARGER
SETTINGS
NOTE: The battery charger algorithm profi le is
programmed for Trojan fl ooded (wet) lead acid
batteries 160-260 AH range (Algorithm position 003 -
factory defaULT). Program the charger algorithm profi le
according to specifi c battery type as described below
to prevent battery damage.
1. Disconnect the charger power cable from the wall
outlet or the charger. Wait 30 seconds for the input
relay to open.
2. While reconnecting AC input, press and hold the
Select Charge Profi le Button for approximately 10
seconds, through the light check function, until the
Error Indicator is illuminated (amber) and Battery
Charging Indicator starts fl ashing (green).
3. Press and release the Select Charge Profi le
Button to advance through the charge profi les. The
selected charging profi le will be displayed up to
three times.
NOTE: Process will time out and profi le will remain
unchanged if there is 15 seconds of inactivity. A profi le
number is allowed to display three times.
4. When the new charging profi le is displayed, press
and hold the Select Charge Profi le button for
10 seconds to confi rm selection and exit Profi le
Selection Mode. When the charge profi le is
confi rmed, the Error Indicator and Battery Charging
Indicator lights will turn off and the blue AC Power
Indicator will remain illuminated. Release the
Select Charge Profi le button.
5. Press the Select Charge Profi le Button to ensure
the new profi le is selected.
Algorithm
Profi le ID
Battery Description
003
Trojan fl ooded batteries 160-260 AH
range
021
TAB/ENERSYS fl ooded batteries 180-
260AH Range
028
DEKA GEL batteries 180-200 AH range
043
DISCOVER AGM batteries 200-400 AH
range
051
SONNENSCHEIN GEL batteries 200-
400 AH range
168
TPPL, 12XFC48/12XFC58/12XFC60
Changing the Off-Board Battery Charger Setting instructions
and photos taken from the Delta-Q IC650 Charger Manual.
© Delta-Q Technologies Corp. (PN: 710-0138 Rev 3
Date: 14/07/2014)
Summary of Contents for t500
Page 5: ...5 T500 9015504 01 2018 CONTENTS ...
Page 55: ...55 T500 9015504 01 2018 TROUBLESHOOTING ...
Page 89: ...89 T500 9015504 01 2018 SERVICE 9 Cycle the key switch to save selections ...
Page 111: ...111 T500 9015504 01 2018 SERVICE ...
Page 117: ...117 T500 9015504 01 2018 SERVICE ...
Page 146: ...146 T500 9015504 01 2018 SERVICE ...