Page 3 of 9
KIT NO. 9006828
T5e
ec-H2O
Kit
INSTALLATION INSTRUCTIONS --
Continued
9006829 Rev. 00 (12--09)
Tennant Company
Customer Service: (800) 553--8033 or (763) 513--2850
10. Route the following
ec--H2O
harness wires
(Figure 12) as described in step 11.
To Pressure
Switch
To Horn
To Pump
Fig. 12
11. Route the above
ec--H2O
harness wires to the
scrub head assembly as shown (Figure 13).
Route
Harness
Fig. 13
12. Arrange the
ec--H2O
wire harness within the
circuit breaker box as shown (Figure 14).
Harness
Wires (C)
To Control
Console
Fig. 14
12. Replace circuit breaker box cover (Figure 15).
Fig. 15
INSTALL THE
ec- H2O
CONTROL CONSOLE
COMPONENTS:
1. Remove the upper control panel from the control
console and locate the routed
ec--H2O
harness
wires (Figure 16).
Fig. 16
2. Remove the components from the upper control
panel
(take note of wire connections before
removing)
. Using new panel [p/n 1041719] and label
[p/n 1050010], re--install components (Figure 17).
Install
ec--H2O
LED light [p/n 1041822] as shown.
LED Light
[p/n 1041822]
Remove components
New Panel [p/n 1041719]
New Lable [p/n 1050010]
Fig. 17
Home
Find...