OPERATION
Tennant T5e (09--08)
13
IMPORTANT:
NEVER turn the FaST/ec--H2O system
switch on when conventional scrubbing. Conventional
cleaning detergents/restorers may cause failure to the
FaST/ec--H2O solution system. Drain, rinse and refill
solution tank with cool clean water before operating the
FaST/ec--H2O system.
FIG. 19
4. Lower the squeegee assembly to the floor by
lowering the squeegee lift lever (Figure 20).
FIG. 20
5. Lower the scrub head to the floor by pressing the
brush pressure button (Figure 21).
FIG. 21
6. Pull the triggers to begin scrubbing (Figure 22). To
reverse the machine, simply pull the reverse
trigger. Raise squeegee when reversing machine.
FIG. 22
7. Adjust the speed control knob to a desired
scrubbing speed (Figure 23).
NOTE:
45--60 meters per minute is the recommended
scrubbing speed.
FIG. 23
8. Check the brush pressure meter reading and adjust
the pressure if needed (Figure 24). Do not operate
the machine in the red zone, floor damage or brush
motor overload may result.
FIG. 24