SUPERVISOR CONTROLS
Tennant T600 EE (04-2018)
41
SUPERVISOR CONTROLS
ATTENTION:
The following instructions are intended
for supervisor use only. Remove pages from manual if
necessary.
The supervisor controls feature allows a supervisor to
program the machine's scrubbing settings for operator
use. The lockout functionality will prevent the operator
from changing or saving scrub settings.
The supervisor controls feature will lower machine
variability for consistent, repeatable cleaning results,
provide machine quality assurance regardless of user
experience, and reduce user training requirements.
USING SUPERVISOR CONTROLS
The machine has three supervisor control modes of
operation to choose from:
Unlocked Mode 1:
Operator has full control of all
scrubbing parameters with the ability to reconfigure the
preset zone control buttons. The Unlocked Mode 1 is
the factory default setting.
Lockout Mode 2:
Zone control buttons are preset and
locked by supervisor. Operator has the ability to
reconfigure the preset zone control buttons, but are not
able to save them.
Lockout Mode 3
: Zone control buttons are preset and
locked by supervisor. Operator is restricted to only use
the zone control buttons preset by supervisor.
Entering the Supervisor Control Modes
1. Park the machine on a level surface and turn the
key to off ( O ) position.
2. Press and hold the brush pressure button while
turning the key on. Release button when the far
right battery discharge indicator LED turns on
(Figure 84). After releasing button, the active
supervisor control mode will display as described in
step 3 (Figure 85),
FIG. 84
3. To select or change a supervisor control mode,
press and hold the specific zone control button until
the LED blinks three times (Figure85). For lockout
mode 3, press and hold zone control buttons 1 and
2 at same time. After selection is made, the LED
will turn solid to indicate new mode.
Unlocked mode 1 = Zone control button 1
Lockout mode 2 = Zone control button 2
Lockout mode 3 = Zone control buttons 1 & 2
Unlocked Mode 1
Lockout Mode 2
Lockout Mode 3
FIG. 85
4. Press the solution flow button to configure the zone
control button presets for lockout modes 2 or 3
(Figure 86).
FIG. 86
5. Configure the zone control button presets from list
below, then press and hold zone control button
until it blinks three times to save preset. Repeat
process for other two zones. To preset zone
control 3, press zone control buttons 1 and 2 at the
same time.
Zone control presets:
- Brush pressure rate
- Solution flow rate
- Quiet-Mode button on or off
- Maximum scrubbing speed setting
To adjust the maximum scrub speed setting, press
the area (hidden button) on the panel as shown to
cycle through the five speed selections as
described below (Figure 87).
The speed selection is displayed by the battery
discharge indicator LEDs. The red LED represents
the lowest speed. The far right green LED
represents the highest speed (Figure 87).
Low
→
High
Speed Selection
FIG. 87
NOTE: The maximum scrub speed setting can only be
adjusted in supervisor control lockout modes 2 and 3.
6. To exit the supervisor control mode, turn key off.