146
T600/T600e 9016605 (04-2018)
SERVICE
10. Install the new vacuum fan onto the mount bracket.
Be sure the vibration isolators are completely
inserted into the vacuum fan.
11. Install new vacuum fan assembly / reinstall the
removed vacuum fan assembly in the reverse order
of disassembly.
REMOVING / INSPECTING / REPLACING THE
RECOVERY TANK VACUUM FAN CARBON
BRUSHES
FOR SAFETY: Before leaving or servicing machine,
stop on level surface, turn off machine, remove
key, and set parking brake if equipped.
FOR SAFETY: When servicing machine, Disconnect
battery connection and charger cord before
working on machine.
NOTE: Carbon brushes should be replaced as sets.
1. Remove the vacuum fan from the machine. See
REMOVING / INSTALLING THE VACUUM FAN.
2. Remove the hardware securing the vacuum fan
cover assembly to the motor and remove the
vacuum fan cover assembly from the vacuum fan
motor.
3. Loosen the carbon brush mounting hardware.
4. Remove the carbon brushes from the vacuum fan
motor.
5. Inspect carbon brushes. Replace carbon brushes if
they are stuck or are less than 10 mm (0.375 in) in
length.
Summary of Contents for T600e
Page 13: ...T600 T600e 9016605 04 2018 13 GENERAL INFORMATION T600 ELECTRICAL SCHEMATIC PAGE 1 1 2 3 5 4...
Page 14: ...14 T600 T600e 9016605 04 2018 GENERAL INFORMATION T600 ELECTRICAL SCHEMATIC PAGE 2 1 2 3 5 4...
Page 15: ...T600 T600e 9016605 04 2018 15 GENERAL INFORMATION T600 ELECTRICAL SCHEMATIC PAGE 3 1 3 2...
Page 16: ...16 T600 T600e 9016605 04 2018 GENERAL INFORMATION T600 ELECTRICAL SCHEMATIC PAGE 4 1 2 3...
Page 17: ...T600 T600e 9016605 04 2018 17 GENERAL INFORMATION T600e ELECTRICAL SCHEMATIC PAGE 1 1 2 3 5 4...
Page 18: ...18 T600 T600e 9016605 04 2018 GENERAL INFORMATION T600e ELECTRICAL SCHEMATIC PAGE 2 1 2 3 5 4...
Page 19: ...T600 T600e 9016605 04 2018 19 GENERAL INFORMATION T600e ELECTRICAL SCHEMATIC PAGE 3 1 2...
Page 20: ...20 T600 T600e 9016605 04 2018 GENERAL INFORMATION T600e ELECTRICAL SCHEMATIC PAGE 4 1 2...