156
T600/T600e 9016605 (04-2018)
SERVICE
REMOVING / REPLACING / INSTALLING THE
AUTO-FILL ASSEMBLY
6.7 gpm
float valve
Auto-fill
bracket
gasket
Auto-fill
bracket
QD male
straight fitting
QD female
straight fitting
(hose coupler)
1. Drain all solution from the recovery tank.
2. Drain the solution tank until the water level is below
the auto-fi ll assembly. Check solution level in the
solution tank on the solution tank level/drain hose.
FOR SAFETY: Before leaving or servicing machine,
stop on level surface, turn off machine, remove
key, and set parking brake if equipped.
3. Turn the key to the OFF position.
4. Remove the hose coupler from the auto-fi ll
assembly.