A1.6 Replacement of centre brush
Disassembly
1
Move the machine onto flat and dry flooring.
2
Make sure that there is enough room around the machine to perform the dismantling operations safely.
3
If necessary, clean the working area with a jet of compressed air, or a vacuum cleaner.
4
Remove the battery.
5
Release the fixture of the arm on both sides.
6
Lay the machine down so that the brush compartment is exposed.
7
Turn the brush to the point at which a black key positioned at the left hand end can be seen.
8
Depress the black key and push the brush inwards.
9
Remove the worn centre brush and proceed to fit the new brush, making certain that it is locked in place by the
black key.
The brush will need to be replaced generally as the result of normal wear.