16
Additional connectors:
1. The O / S / C input
allows you to connect a switch to control the drive (Fig. 19).
2. The signal lamp
(Fig. 18 and Fig. 19).
The drive has a separate output signal lamp. Supplying the signaling lamp it should be in
the 24 V - 28 V DC range and the current consumption must not exceed 100 mA. When
using AC 230 V signal lamps, additional relays should be used.
3. Pass door protection
(Fig. 19).
This function does not allow the gate to be opened when the small wicket door is open.
Thanks to this, the door panel will not be damaged.
SD
AC 230 V
IN
FLASH
LIGHT
(AC 230 V)
+24
PE
PB
GND
GND
FLASH
Relay
Fig. 18
Fig. 19
GARAGE DRIVE
pass door
protection device
caution light
O/S/C
SD
+24 PE
PB
GND
GND