background image

BLEACH

• Do not use M.E.K.(methyl ethyl ketone) 

   to try and clean your inflatable, as this 

   will damage the vinyl 

• Do not use a chlorine based cleaner or 

   bleach, as this may damage the threads

• Do not use any cleaning products 

   containing alcohol to try and clean your 

   inflatable device, as this will damage any 

   printing that may be on your inflatable 

• Use water and/or mild cleaner sparingly 

   by sponging

• Excessive water or cleaner may penetrate 

   the seams and collect inside of the tubes 

   —also, bubbling from the seams during 

   operation may occur 

CLEANING THE INFLATABLE

Next, align unit

into a rectangle

shape—pancake

top and bottom

Front

Deflation Tubes

—Back of unit,

keep extended

888 322-5606 (toll free)

• 

Before deflating;

 Inspect for any damage 

   and repair as necessary 

• 

Clean 

inflatable amusement device(s) 

and 

   dry

, after use—by running air through it

• Unplug blower at the power source 

• Loosen first inflation/deflation tube 

   strap and remove tube from blower cone 

   —make sure tube is pulled away from 

   the inflatable and is straight 

• Loosen second inflation/deflation tube 

   strap and pull tube away from inflatable 

• Open all deflation flaps

• While the inflatable amusement device 

   is deflating, remove stakes, put blower 

   fan away, and store extension cord(s) 

• Two people, minimum, needed to fold

• Guide inflatable inward and to the front

   —while the air is being released

• Begin folding inflatable amusement 

   device—pull vertical peaks/shapes toward 

   the front, to flatten and release more air

• Next, situate top of unit over the bottom,

   pancake style—and fold peaks into the 

   middle, see (

drawing

)

• Once you make the folds, you will notice 

   that air is still inside the game—start at 

   the front and walk, in stocking feet, to 

   the back—removing most of the air 

• Work the air out towards the back of 

   the unit through the inflation tube(s)

• Commercial inflatables take 5–15 

   minutes to completely deflate 

DEFLATION AND FOLDING- cont.

DEFLATION AND FOLDING

5

Before deflation, remove all accessories that may be

applicable to your unit—also be sure to use a quality 

broom and sweep the surface of the game free of 

any debris

Check to make sure that no sharp 

objects have fallen into the seams 

of the game, Eg. pens, pencils, etc.

—items such as these can cause 

damage to the inflatable during 

the rolling up process

Summary of Contents for GA Bounce Kaleidoscope Castle 7013

Page 1: ...l free Instruction Manual INFLATABLE AMUSEMENT DEVICE BOUNCE HOUSES GENERAL INSTRUCTIONS RC 7013 GA Bounce Kaleidoscope Castle 1612NBroadStreet 44WRidgePike Lansdale Pa 19446 Limerick Pa 19468 215 362 7368 610 489 2334 ...

Page 2: ...UP STEP 1 SAFETY CHECK LIST 1 Use Ground Cover Tarps to protect inflatable Secondary escape opening in roof Must be positioned on a FLAT LEVEL SURFACE Anchor Straps at base secure with recommended stakes refer to your state inspection requirements 2 trained operator attendants are required to supervise this device at all times GFCI extension required reduces possibility of shock Commercial Inflatabl...

Page 3: ...hammer ground tarp hand truck or 4 wheel dolly crowbar stake remover safety goggles GFCI extension adapter 50 12AWG extension cord Carefully place unit using dolly at one end of tarp it s easier to move at this stage See drawing find back end of inflatable device and roll onto tarp Make a mental note or snap a picture of how the inflatable is folded and positioned as you unroll the game This will be ...

Page 4: ...the way in hook end should be touching the ground Slide stake through D ring and position hook away from inflatable SOIL CONSISTENCY Stake in Hard Stiff or Medium soil DO NOT Stake in Soft soil check ASTM f2374 17 standards Slide feet first only Do not slide head first CORRECT One at a time No double sliding ARMS CROSSED FEET TOGETHER Do not touch sides with hands or feet all the way down SET UP STEP ...

Page 5: ...sement device and at least 5 feet away from the sides Starting line is 48 inches from the entry of the inflatable amusement device Prohibit excessive rough play by occupants blow whistle In times of excessive heat monitor the heat inside play area and slide surface Do not allow any individual in the rear of the game or near the electric blower at any time Deny entry if any patron poses a risk to ot...

Page 6: ...cond inflation deflation tube strap and pull tube away from inflatable Open all deflation flaps While the inflatable amusement device is deflating remove stakes put blower fan away and store extension cord s Two people minimum needed to fold Guide inflatable inward and to the front while the air is being released Begin folding inflatable amusement device pull vertical peaks shapes toward the front to flatte...

Page 7: ...tight slip knot around the roll Stand the inflatable amusement device on end place the transport storage bag over one end of the game and work it down as far as you can It is important that you work the bag down to the top of the roll flip the unit and pull the bag up over the top of the inflatable amusement device Tie the bag closed Lay the game onto a dolly and roll it to your designated storage ar...

Page 8: ... EVACUATION PLAN In the case of rapid deflation or poor weather during operation attendants should follow these steps Operator attendants should blow whistles to evacuate patrons immediately and safely aid child patrons as they exit then tell them to step away from inflatable device Any patrons on elevated platforms should climb down the stairs backwards if a patron is sitting ready to slide let tha...

Page 9: ...S 14 x 12 5 x 15 5 INFLATION DEFLATION TUBES 2 DEFLATION FLAPS 1 DEVICE CAPACITY 6 Patrons BLOWER 1 1 0 HP MINIMUM NUMBER OF TRAINED ATTENDANTS 2 MINIMUM HEIGHT MAXIMUM HEIGHT 36 in 60 in ANCHORS TIE DOWNS 4 0 MAXIMUM WEIGHT 250 lbs per patron 600 lbs total limit SKU XBH RNBWMOD 14A 4 anchor straps 1 on each corner entrance exit 15 1 2 5 14 8 ...

Page 10: ...epair until you can apply the Single Patch Method or send the unit to a repair facility DAILY CHECKLIST Ensure maximum winds are less than the manufacturer s recommended wind speed requirement for unit Ensure temperatures are greater than 40 F Ensure that a minimum 12 gauge 3 wire extension cord is used with the blower and is connected to a CFCI Ground Fault Circuit Interrupter Ensure there are no...

Page 11: ...NIT REQUIRES A CONSTANT SOURCE OF 110V 20amp POWER PER BLOWER SYSTEM SAFETY RULES A MINIMUM OF TRAINED OPERATOR S MUST BE ON DUTY AT ALL TIMES ADULT SUPERVISION REQUIRED AT ALL TIMES Compliance Statement The vinyl and netting material used in the construction of this product is of the highest quality 100 lead free adheres to MFR methods and was built to ASTM F2374 standards NO SHOES NO UNEVENLY MA...

Reviews: