Rev_02/2018
17
STEP
#9
A
~
F
IX THE HOSE TO THE HAND SHOWER
.
ÉTAPE
#9
A
~
R
ATTACHER LE BOYAU À LA DOUCHETTE
.
Rev_02/2018
18
T
ROUBLE SHOOTING
S upply of hot and cold water lines are rev ers ed.
Interchange the water s upply hos es
1 - W ater hose pinched or s queezed from behind.
Make s ure that the hos es are well pos itioned and are
not pinched or s queezed any where.
2 - W ater pres s ure inferior to 35 ps i.
(Thermos tatic v alv e)
A - Water s upply from the city .
No pos s ible s olution
B - W ater s upplied by well.
Increas e the pres s ure of y our pump.
3 - Debris at the entrance of the check v alv e.
Remov e the faucet from the wall, dis connect the hot
and cold connectors from the v alv e and remov e all dirt
and debris .
4- Hard water
Soak the thermostatic cartridge in a (50/50) s olution of
water and v inagar, for 12h. Cons ult the cartridge
remov al manuel for ins trutions before s tarting .
1 - The rain s hower head is placed horizontally .
Place y our rain s hower head at an angle to allow the
water to drain.
2 - The handle of the rain s hower head v alv e does not
clos e properly .
Contact Tenzo for a cartridge replacement .
1 - The temperature of y our water heater is not
adjus ted to 60 ° C (140 ° F).
Make the adjus tment of the temperature of y our water
heater.
2 - Debris at the entrance of the check v alv e.
Remov e the faucet from the wall, dis connect the hot
and cold connectors from the v alv e and remov e all dirt
and debris .
3 - Temperature knob is in the wrong pos ition.
Contact Tënzo for pos s ible adjus tement of the
thermos tatic cartridge.
1 – Pres sure lower than 35 ps i.
No s olution pos s ible.
2 - W ater line ov erloaded.
Feed directly into the main s upply .
No t T e mp e r e d (Ho t o r C o l d o n l y )
Lo w p r e s s u r e o r n o w a t e r
T h e r a i n s h o w e r h e a d c o n t i n u o u s l y d r i p s a f t e r u s e
W a t e r t e mp e r a t u r e t o o h o t o r t o o c o l d a t t h e t w e l v e o 'c l o c k p o s i t i o n
C h a n g e i n t e mp e r a t u r e