OPERATING MANUAL
OPERATING MANUAL
English
GB
English
GB
GB
GB
HIGH FREQUENCY MODE
Approach the work piece with the torch up to a dinstance of
3-5 mm. from tungsten.
Push the torch switch to strike the arc; if the arc doesn’t ignit,
the high frequency impulse stops after 4 seconds. Drive again
the torch switch.
In particular environment conditions such as hospitals, aerports, active nuclear plants, etc. the high frequency
should be forbitten.
In that case, deselect the high frequency and use only lift arc start.
Press “+” and “-” pushbuttons to select or
deselect the high frequency mode
Press the second level pushbutton up to
the icon “HF” flash
CURRENT SETTING – Manual
Press the first pushbutton and select “TIG” or “TIG PULSE”
Press the second pushbutton and select “MANUAL”
With the third pushbutton select the electrode diameter
Set with pushbuttons “+” or “-” the required welding current