Figure 4 - Front-panel mounting (left image); back-panel mounting (right images)
2.3.
Mounting solutions
When choosing a place for mounting the TeraRanger Evo People Counter, please
consider the following recommendations:
●
Mounting close to sources of heat or strong electromagnetic fields can decrease
sensor performance
●
Do not mount anything directly in front of the sensor or in a cone of
approxi/-35° around the central optical axis of the sensor
●
It is advisable to avoid having other sources of Continuous Wave or modulated
Infrared light sources near the sensor
●
Please consider that dust, dirt and condensation can affect sensor performance
●
It is not advised to add an additional cover in front of the sensor without any
custom calibration (contact Terabee)
●
For an optimal placement of the People Counting sensor, please follow this
Copyright
©
Terabee 2021
Terabee, 90 Rue Henri Fabre
01630, St Genis-Pouilly, France (next to CERN)
8/19
During assembly and integration, please observe all common ESD precautions. All
optical surfaces (sensor front) should be kept clean and free from contact with
chemicals.