Figure 4-14 Voltage Sequencer Customizer General Tab
For this example project, the key parameter settings are the number of rails (4), Auto Power Up and
Auto Power Down settings and Rail Fail interrupts. Those settings enable the component to
automatically sequence the regulators up and down with minimal firmware. Refer to
AN62496
for
full details of the configuration options presented here.
Click on the
Rails Tab
to setup the voltage regulator controls, primarily used in this example project
to set the polarity of the regulator enable signals to active high for compatibility with the regulators
installed on the PSoC Power Management EBK. (See
Figure 4-15
)
Figure 4-15 Voltage Sequencer Customizer Rails Tab
Click on the
Sequencer Tab
to configure the sequencing options. In this example project, each rail
is assigned its own sequencing time slot. The matrix of checkboxes currently shows that timing slot
22