Trouble shooting
Alarm message 97 to 108
ã
Terberg Machines B.V., IJsselstein, The Netherlands
All rights reserved. No part of this book may be reproduced, stored in database or retrieval system, or published, in any form or in any way,
electronically, mechanically, by print, photoprint, microfilm or any other means without prior written permission from the publisher.
97: 4W HEIGHT SENSOR
N29 FAULT
OmniDEKA bin lift:
Sensor (N29) output fault, the sensor stays in
“ON” condition.
This sensor detects 1100 ltr. containers.
If no trade container is present on the bin lift,
please check the sensor, check the sensor area for
objects and check the cables to sensor (N29).
98:
Not used.
99: PRESSURE TOO HIGH
L/H CALIBRATION MODE
Only during calibration mode.
Hydraulic oil pressure was too high when moving
the bin lift, at the moment position sensor calibra-
tion is active.
At the end of cylinder strokes this is normal.
If this occurs halfway cylinder strokes please check
the mechanical construction and the valves.
100: PRESSURE TOO HIGH
R/H CALIBRATION MODE
101: LH HS1
DUAL WIPER FAILURE
102: LH HS2
DUAL WIPER FAILURE
103: RH HS1
DUAL WIPER FAILURE
104: RH HS2
DUAL WIPER FAILURE
105: L/H WINDOW READY
MOVE CHAIR DOWN
Only during pressure weighing calibration mode
active on L/H side.
If you perform the max weight calibration
(reference weight on the chair) this message will
show on the display and the bin lift will stop lifting
when it has fully passed the weighing window. This
is to avoid the bin with weight will reach the tipped
position.
106: R/H WINDOW READY
MOVE CHAIR DOWN
Only during pressure weighing calibration mode
active on R/H side.
If you perform the max weight calibration
(reference weight on the chair) this message will
show on the display and the bin lift will stop lifting
when it has fully passed the weighing window. This
is to avoid the bin with weight will reach the tipped
position.
107: 4W WINDOW READY
MOVE CHAIR DOWN
Only during pressure weighing calibration mode
active in 4-wheel (trade) mode.
If you perform the max weight calibration
(reference weight on the chair) this message will
show on the display and the bin lift will stop lifting
when it has fully passed the weighing window. This
is to avoid the container with weight will reach the
tipped position.
108: R/H HS1 (TILT)
ERRATIC READING
A position sensor difference error caused by
position sensor HS1 on the R/H side.
Linearity check.
This is a timer based interval check, with the bin lift
in motion it checks the old position value and the
current position value. If the difference in position
is too big, this event is remembered in a counter.
When the value of this counter reaches a selected
maximum nr. of errors (5), this message is display-
ed.
Check for axial and radial play where HS1 is
located.
Check the magnet from position sensor HS1.
Check the position sensor HS1.
Check the sensor signal on analogue input 00.2
Check cables and connectors to HS1.