4 - 2
DPL-25S • DPL-30S • DPL-35S Super Series
Part No. 40462
September 2016
Section 4 - Scheduled Maintenance Procedures
A-1
Inspect the Operator’s and
Responsibility Manuals
Maintaining the operator’s and responsibility
manuals in good condition is essential to safe
machine operation. Manuals are included with
each machine and should be stored in the
container provided at the platform. An illegible or
missing manual will not provide safety and
operational information necessary for a safe
operating condition.
1 Check to be sure the storage container and lid
are present and in good condition.
2 Check to make sure that the operator’s and
responsibility manuals are present and
complete in the storage container at the
platform.
3 Examine the pages of each manual to be sure
that they are legible and in good condition.
4 Always return the manuals to the storage
container after use.
Note: Contact your authorized Genie distributor or
Genie if replacement manuals are needed.
A-2
Inspect the Decals and Placards
Maintaining all of the safety and instructional
decals and placards in good condition is essential
for safe machine operation. Decals alert operators
and personnel to the many possible hazards
associated with using a machine. They also
provide users with operation and maintenance
information. An illegible decal will fail to alert
personnel of a procedure or hazard and could
result in unsafe operating conditions.
Table A Procedures
1 Refer to the
Decals
section in the
Genie DPL
Super Series Operator's Manual
and use the
decal list and illustrations to determine that all
decals and placards are in place.
2 Inspect all decals for legibility and damage.
Replace any damaged or illegible decal
immediately.
Note: Contact your authorized Genie distributor or
Genie if replacement decals are needed.
A-3
Inspect for Damage and Loose or
Missing Parts
Daily machine condition inspections are essential
to safe machine operation and good machine
performance. Failure to locate and repair damage,
and discover loose or missing parts may result in
an unsafe operating condition.
1 Inspect the entire machine for damage and
improperly installed or missing parts including:
• Electrical components and wiring
• Coil cord (if equipped)
• Hydraulic power unit, hoses, fittings and
cylinders
• Manual lowering lever and components
• Platform end guard rail, platform side guard
rails and platform entry gate
• Guard rail lock handles
• Sequencing cables and pulleys
• Lifting chains and idler wheels
• Nuts, bolts and other fasteners
• Mast and mast braces
• Breather cap
• Outriggers, leveling jacks and footpads
• Guard rail lift arm
• Platform entry ladder
• Dents or damage to machine
• Corrosion or oxidation
• Cracks in welds or structural components