Part No. 40462
DPL-25S • DPL-30S • DPL-35S Super Series
5 - 23
September 2016
Section 5 - Troubleshooting Flow Charts
Chart 10
Power Unit
Will Not Lift
Rated Load
Check the pressure relief
valve setting. See
Maintenance procedure,
Test the Lifting Capacity.
Check the power source.
Note on DC models the
low battery indicator (red
LED) light would be on
indicting a low voltage
condition.
low
voltage
Adjust the pressure relief
valve. See Repair
procedure, How to Adjust
the Pressure Relief
Valve.
incorrect
correct
Charge the battery OR
check battery condition
and replace bad battery
OR use the appropriate
power cord OR consult
Genie Industries Service
Department.
Consult Genie Industries
Service Department.
good