Operator's Manual
Fifth Edition • First Printing
10
GR-12 • GR-15 • GR-20
Part No. 133571
Tip-over Hazards
Occupants, equipment and materials must not
exceed the maximum platform capacity or the
maximum capacity of the platform extension.
Weight in trays are part of the total platform load.
Maximum capacity - GR-12 and GR-15
Standard platform
Platform without extension
500 lbs
227 kg
Platform retracted
500 lbs
227 kg
Platform extended - Platform only
250 lbs
113 kg
Platform extended - Extension only 250 lbs
113 kg
Work station tray (option)
50 lbs
22 kg
Maximum occupants
1
500 lbs / 227 kg Extension only Platform only
250 lbs / 113 kg 250 lbs / 113 kg
Electrocution Hazards
This machine is not
electrically insulated and
will not provide protection
from contact with or
proximity to electrical
current.
Maintain safe distances
from electrical power lines
and apparatus in
accordance with applicable
governmental regulations
and the following chart.
Line Voltage
Required Clearance
0 to 50KV
10 ft
3.05 m
50KV to 200KV
15 ft
4.60 m
200KV to 350KV
20 ft
6.10 m
350KV to 500KV
25 ft
7.62 m
500KV to 750KV
35 ft
10.67 m
750KV to 1000KV
45 ft
13.72 m
Allow for platform movement, electrical line sway
or sag and beware of strong or gusty winds.
Keep away from the machine if it contacts
energized power lines. Personnel on the ground or
in the platform must not touch or operate the
machine until energized power lines are shut off.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
Work Area Safety
AWP platform
350 lbs
159 kg
Maximum occupants
1
Summary of Contents for Genie GR-12
Page 1: ......