19
B-2 Ins pect t he Elect rical Wiri ng
B-2
Inspect the Electrical Wiring
Genie requires that this procedure be performed
every 250 hours or quarterly, whichever comes
first.
Maintaining electrical wiring in good condition is
essential to safe operation and good machine
performance. Failure to find and replace burnt,
chafed, corroded or pinched wires could result in
unsafe operating conditions and may cause
component damage.
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
1 Open and remove the turntable covers from
the machine.
2 Turn the key switch to ground control and pull
out the red Emergency Stop button to the on
position at both ground and platform controls.
Note: Rotate the red Emergency Stop button at
platform control one quarter turn in a clockwise
direction to restore the power supply. The red
Emergency Stop button returns automatically to
the out, or on position.
3 Raise the jib boom until the platform is
approximately 8 feet / 2,4 m from the ground.
4 Turn the key switch to the off position and
push in the red Emergency Stop button to the
off position at the ground controls.
5 Tag and disconnect the cables from the
ground terminal of the battery.
6 Remove the fasteners securing the rear
chassis cover to the chassis at the non-steer
end of the machine. Remove the chassis
cover. Lay the cover and fasteners to the
side.
7 Inspect the drive motors connections for
burnt, chafed, pinched cables and loose
connections.
8 Install the rear chassis cover at the non-steer
end of the machine and securely install the
fasteners.
9 Install the cables onto the ground terminal of
the battery, and securely tighten.
10 Inspect the battery pack for burnt, chafed and
pinched cables.
11 Inspect the following areas for burnt, chafed,
corroded, pinched and loose wires:
•
Ground control panel
•
Battery charger
•
Hydraulic power unit
12 Turn the key switch to ground control and pull
out the red Emergency Stop button to the on
position.
Note: Rotate the red Emergency Stop button at
platform control one quarter turn in a clockwise
direction to restore the power supply. The red
Emergency Stop button returns automatically to
the out, or on position.
Summary of Contents for Genie GR-20J
Page 77: ...March 2022 Service Manual Function Manifold Part No 1312899GT GR 20J GR 26J 65 ...
Page 113: ...March 2022 Service Manual 101 Electrica l Schemati cs Electrical Schematic GRJ from GRJL 2298 ...
Page 116: ...Service Manual March 2022 104 Electrical Schematic GRJ from GRJL 2298 ...
Page 117: ...March 2022 Service Manual 105 GCON LED Panel GRJ from GRJL 2298 ...
Page 120: ...Service Manual March 2022 108 Temperature Sensor Harness GRJ from GRJL 2298 ...
Page 121: ...March 2022 Service Manual 109 Options GRJ from GRJL 2298 ...
Page 127: ......