March 2021
Service and Repair Manual
Type "CXXX" Faults
Part No. 1272217GT
GS
™
-30 • 32 • 46 • 47
177
Type "CXXX" Faults
DTC
Number
Message on
GCON LCD
Description
Possible Causes
Failure Mode
C001:
GS30,
GS32,
GS46 &
GS47
C001:GCON ECM
FAULT TYPE 1
GCON ECM CRC check error.
• Incorrect software file.
• GCON ECM internal failure.
All functions
inhibited.
C004:
GS30,
GS32,
GS46 &
GS47
C004:GCON ECM
FAULT TYPE 4
GCON ECM master switch error.
• Short circuit in the master switch circuit.
• GCON ECM.
All functions
inhibited.
C005:
GS30,
GS32,
GS46 &
GS47
C005:GCOM ECM
FAULT TYPE 5
GCON ECM safety switch error.
• Short circuit in the safety switch circuit.
• GCON ECM.
All functions
inhibited.
C006:
GS30,
GS32,
GS46 &
GS47
C006:GCON ECM
FAULT TYPE 6
GCON input redundancy error.
• Input conditioning circuit failure.
• GCON ECM.
All functions
inhibited.
C007:
GS30,
GS32,
GS46 &
GS47
C007:GCON ECM
FAULT TYPE 7
GCON ECM inter-processor communication
error.
• Incorrectly programmed device.
• Error in loading software on device.
• GCON ECM.
All functions
inhibited.
C009
:
GS30;
GS32'
GS46 &
GS47
C009:GCON ECM FAULT
FAULT TYPE 9
GCON ECM fault type 9.
• Contact Genie support.
All functions
inhibited.
C010:
GS30,
GS32,
GS46 &
GS47
C010:SECONDARY
NOT PROGRAMMED
GCON secondary processor not
programmed.
• Incorrectly programmed device.
• Error in loading software on device.
• GCON ECM.
All functions
inhibited.
C021:
GS30,
GS32,
GS46 &
GS47
C021:PCON NOT
DETECTED
PCON not detected error.
• PCON disconnected.
• CAN communication failure.
• GCON or PCON ECM.
All functions
inhibited.
C023:
GS30,
GS32,
GS46 &
GS47
C023:MACHINE
MODEL FAULT
Discrepancy between model detected and
model programmed.
• Incorrect machine model programmed.
• GCON or PCON ECM.
All functions
inhibited.
C025:
GS30,
GS32,
GS46 &
GS47
C025:SYSTEMFAULT
PLAT OVLD:NOCAL
Platform overload system not calibrated.
• Platform overload system not calibrated.
• GCON or PCON ECM.
All functions
inhibited.