March 2021
Service and Repair Manual
Battery Charger
Part No. 1272217GT
GS
™
-30 • 32 • 46 • 47
181
Charger Error Codes
Charger Error Codes
Error Code
Description
Condition
Possible Causes
E-0-0-1
High battery voltage
Battery voltage too high to charge.
Check battery voltage and cable
connections.
Self clearing when condition has
been corrected.
E-0-0-2
Low battery voltage detected prior to
starting charge cycle
Battery voltage too low to charge.
Check battery voltage and cable
connections.
Check battery condition.
Self clearing when condition has
been corrected.
E-0-0-3
Charge timeout
Charge timeout caused by battery
pack not reaching required voltage
within safe time limit.
Charge output reduced due to
high temperature. Charge at
lower temperature.
Check battery condition.
Replace damaged battery.
Check battery connections.
Battery pack deep discharge.
Disconnect battery pack for
30 seconds to clear fault when
condition has been corrected.
E-0-0-4
Defective battery
Battery pack could not be trickle
charged up to the minimum voltage.
Check battery condition.
Replace damaged battery.
Check battery connections.
Disconnect battery pack for
30 seconds to clear fault when
condition has been corrected.
E-0-0-7
Amp hour limit exceeded
Safety limit exceeded.
Check battery condition.
Replace damaged battery.
Check battery connections.
Battery pack deep discharge.
High parasitic loads on battery
pack while charging.
Disconnect parasitic loads.
Disconnect battery pack for
30 seconds to clear fault when
condition has been corrected.